MC 785 SC VDH stepper regulator electronic 230V building
  • MC 785 SC VDH stepper regulator electronic 230V building

VDH MC785-SC stepper regulator electronic 230V building

€1,174.00

MC 785 SC VDH stepper regulator electronic

  • surface mounted electronic regulator that steps up to 8 compressors and 
  • 8 condenser fans on and off controls on the basis of the measured suction and discharge pressure and the preset set points. 
  • power supply: 230Vac 
  • steps Number: Max. 70 (with expansion) 
  • Sensor: 4/20 mA 
  • Display: 4 digit
Quantity

EXPERT ADVICE

Professionals in refrigeration technology

SINCE 1986

Since 1986 in refrigeration technology

FACTORY GUARANTEE

You have Always genuine manufacturer's warranty

CUSTOMER SERVICE

+31 413 266 426

info@mfmref.com

Description

VDH MC 785 SC stepper regulator electronic  

  • Electronic step controller that regulates a maximum of 8 compressors and 8 condenser fans on and off based on the measured suction and discharge pressure and the set setpoints.
  • Dimensions: panel 72 x 144 mm; depth = 120 mm.
  • Panel protection: IP65.
  • Direct connection RS485 for connection to network system.
  • Rotation of the steps according to the number of running hours.
  • Minimum and maximum pressure alarm, minimum and maximum failure, minimum and maximum temp. alarm.
  • Sensor exclusive: Standard with 4 / 20mA input.
  • Power supply: 230Vac.
  • Controller 5 relays with output.
  • Structure
  • The MC 785-SC is a step controller that regulates a maximum of 8 compressors and 8 condenser fans on and off based on the measured suction and discharge pressure and the set setpoints.
  • The controller can be set to switch the compressors on power or operating hours.
  • Compressors of different capacities can be used.
  • The controller itself can calculate the best combination of compressors.
  • The condenser fans can be switched on or off based on the total running hours or in a fixed sequence.
  • Compressors and condenser fans can be taken out of the control e.g. i.v.m. maintenance or malfunctions.
  • A minimum and a maximum pressure alarm, a minimum and a maximum pressure alarm, a minimum and a maximum temperature alarm and a minimum and a maximum temperature alarm can be set to monitor the control. The various external faults can be reported on the step controller.
  • As soon as an external fault arrives, the relevant compressor or fan is taken out of the control so that optimal control remains possible.
  • A super-heat alarm can be set on the MC 785-SC to prevent liquid from entering the compressor.
  • All settings and operating options can be authorized by means of a password.
  • There is an RS485 network for controlling the MC785-SC from a PC, via the PC interface and a control program installed on the PC.
  • The MC 785-SC is suitable for surface mounting.
  • The MC 785-SC is supplied with 230Vac as standard.
  • On request the controller can also be supplied for a different supply voltage.