GSR24-NH3-4000 Samon electronic gas leak detection 12-24V AC/DC

 NH 3 (ammonia)

  • Type: GSR24-NH3-4000 
  • Detector with sensor to be mounted above the blow-off pipe at a distance. 
  • Intended for light gases such as ammonia (5m cable) 
  • Power supply: 12-24V AC / DC 
  • Temperatures: -40 ° C to + 50 ° C 
  • Size H x W x D (mm): 160x130x60 
  • Sensitivity ppm: 0-4000 
  • Alarm levels ppm factory setting: 150 - 500-3000 
  • IP class: 54
  • Detectors intended for installation in engine rooms, cold stores or other areas where gas is used, treated or stored.
  • The detectors can be used independently, connected to a monitoring unit or any other monitoring system that accepts potential-free contact.
  • Splash protection
Quantity

EXPERT ADVICE

Professionals in refrigeration technology

SINCE 1986

Since 1986 in refrigeration technology

FACTORY GUARANTEE

You have Always genuine manufacturer's warranty

CUSTOMER SERVICE

+31 413 266 426

info@mfmref.com

Description

Samon GSR24-NH3-4000 electronic gas leak detection 12-24V AC/DC

 NH 3 (ammonia)

  • 160 x 130 x 60  HxBXD
  • - 40°C tot + 50°C
  •  Microprocessor controlled with status display by means of led's.
  •  Built-in service button for pause detection ring during maintenance work for up to 1 hour.
  •  Self test function to check the operation of all leds and detectors.
  •  Fail-safefunctie (error safety function). D.w.z. at power failure, cable break or faulty sensor, the detector automatically in alarm.
  •  The Basic setting of the detectors is to adapt to environmental conditions causing false alarms.
  •  With 3 relay outputs, switching capacity 230V/5A.
  •  The factory setting are on the most sensitive value set to 100-1000-2000 ppm. Possibly itself.
  •  Time delay between detection and alerting is adjustable.
  •  Selection manual or automatic reset possible.
  •  Life sensors ca. 5 years. (CO2 sensors approx. 10 years)
  •  Moisture content: 0 ... 95% Rh (non-condensing)
  •  Note: CO2 models are self calibrating. Advice is to HFC and NH3 models to calibrate with the yearly service tool DT 300 (N501-4275).
  •  At all detectors should be every year a simple self test function and sensor "0" setting