807855 Alco Emerson superheat controller EXD-SH1

As today’s systems require improved energy efficiency, tighter temperature control, a wider range of operating conditions and incorporate new features like remote monitoring and diagnostics,

the application of electronically operated valves becomes mandatory. 

Only these offer the controls performance necessary to meet these needs. Electrical control valves are actuators only.

For operation in a system they need sensors, valve drivers and controllers.

Quantity

EXPERT ADVICE

Professionals in refrigeration technology

SINCE 1986

Since 1986 in refrigeration technology

FACTORY GUARANTEE

You have Always genuine manufacturer's warranty

CUSTOMER SERVICE

+31 413 266 426

info@mfmref.com

Description

807855 Alco EXD-SH1 Emerson superheat controller 

XD-SH1 stand alone superheat and/or temperature controller.

SH1 is intended for the operation of 1 double pole CX/EX/FX valve.

EXD-SH1 is the ideal solution in conjunction with the FX electronic expansion valves for commercial applications.

EXD-SH1 is also the solution together with the EX/CX electronic valves for cooling installations and special applications.

Air conditioning and/or heat pump: R22, R32, R134a, R407C, R410A with valve range FX5 to FX9.

Refrigeration installations: R22, R23, R32, R124, R134a, R407C, R410A, R404A, R507, R407A/F with valve range EX4 to EX8.

Refrigeration installations: R744 with valve range EX4 to EX7 (60 bar), EX8 (45 bar), CX4 to CX7 (120 bar).

Main function EXD-SH1: Circuit 1 > Overheat or temperature control.

Other features such as; Evaporator Pressure Limiting (MOP), Low Pressure Switch, Freeze Protection

and manual adjustment of the valves.

Automatic superheat adjustment along with FX5-9 and CX4-7 series.

Also suitable for most refrigerants ultra low R23.

Modbus (RTU) communication.

Integrated keyboard with dual display.

Monitoring and detection of sensors (ECN/PT5/6)/stepper motor wiring errors.

Low / high overheat alarm as well as other alarm functions.

Electrical connection by means of screw connection plugs supplied with controller

DIN rail mounting.

The required connection cable Micro Molex EXD-M03 can be ordered separately