XR30CX-5N0C1 Dixell elektronischer temperatur regler 230V 20A
  • XR30CX-5N0C1 Dixell elektronischer temperatur regler 230V 20A
  • XR30CX-5N0C1 Dixell elektronischer temperatur regler 230V 20A
  • XR30CX-5N0C1 Dixell elektronischer temperatur regler 230V 20A

XR30CX-5N0C1 Dixell 230V-20A temperatur regler

60,00 €
zzgl. MwSt.

Dixell XR30CX-5N0C1 230V-20A elektronischer temperatur regler

  • XR30CX Dixell Thermostat Installation    
  • IP65 mit manueller Abtauung und RTC 
  • 230 Volt 
  • 2x NTC - Eingang 
  • ohne Summer 
  • Relais 20A Kompressor

 

Menge

BERATUNG FÜR EXPERTEN

Profis in der Kältetechnik

SEIT 1986

Seit 1986 in der Kältetechnik

FABRIKGARANTIE

Immer Original Herstellergarantie

KUNDENSERVICE

+31 413 266 426

info@mfmref.com

Beschreibung

XR30CX-5N0C1 Dixell elektronischer temperatur regler 230V 20A

 

  • Allgemeine Anwendungen
  • Die neue E-CLASS-Baureihe im CX-Format bietet eine Reihe von innovativen Produkten, die Dixell für TK- und NK-Anwendungen entwickelt hat. Dank umfassender Produktkenntnisse und dem Einsatz modernster Soft- und Hardware überzeugt die E-CLASS-Reihe (32 × 74 mm) durch einen hohen Leistungsstandard.
  • Weniger Parameter, einfacher und intuitiver Programmiermodus
  • Tastatursperre, Alarmanzeige
  • Auch für Anwendungen mit geringer Montagetiefe (nur 50 mm)
  • Steigende Trägheit der Temperaturanzeige
  • Neutralzonenregelung
  • Verdichterrelais bis zu 1–2 PS (8 A- oder 20 A-Relais innen)
  • Dezimalauflösung (‑9,9 bis 9,9), zwei Stellen
  • Easy and intuitive installation
  • 9÷40Vdc power supply for refrigerated trucks (for models with 8A compressor)
  • Energy saving cycles triggered via a digital input; for example, it is possible to work at a set point that is different from the normal one in order to, for instance, accumulate cold when electric power is cheaper
  • Continuous cycle with dedicated set; it allows the machine to work during rapid cooling cycles to achieve the right product temperature
  • Regulation stop by auxiliary probe (beer dispenser applications); it is possible to supervise the tube temperature, stopping the compressor when the temperature becomes too low, and restarting when the correct values have been restored
  • Regulation re-start with door switch alarm
  • Max and Min temperature or HACCP function
  • Digital input configurable as probe
  • Virtual probe for air on / air off application; used in multideck applications where it is important to regulate temperature using the average of 2 temperatures
  • Dual thermostat function; is available, on demand, in applications such as white or red wine rooms where it is necessary to maintain 2 different temperatures
  • Condenser temperature management to prevent critical situations in the system
  • Real time clock
  • TTL serial connection for monitoring systems (direct for XR35/75CX or through XJ485CX)
  • Connection for remote display X-REP (excludes TTL 
Artikeldetails
MFMREF153802100966

Besondere Bestellnummern

Anhänge

Download

Dixell XR30CX controller

Dixell XR30CX controller

Download (351.61KB )